ROTEC Lighting Product

Electronic Xenon PSU
1600W
HBX 1600

Modular Electronic Control Gear for DC short arc lamps up to 2000W

Datasheet

Description

Modular Electronic Control Gear for DC short arc lamps up to 1600W

Features

    • Designed for Xenon short arc lamps rated up to 1800W/ 110A
    • Output power selectable by control Voltage 0-5V and/or presetting by Hex switch and adjustment Pot
    • Capable to drive lamp voltage range up to 36V (switch off @ 40V)
    • Ballast boards inside has IEC(UL) 60601 approval and HALT tested
    • Input voltage range from 160V AC to 264V AC, power factor corrected
    • μP controlled, digital power management with high output stability over lamp Lifetime
    • Output short circuit protected and “Arc to Ground” protected
    • Operation with Cathode or Anode to Ground/PE possible
    • Galvanic separation of lamp output to line input, thermal shut off at 90°C
    • Shut off function for end of life and lamp fail parameter
    • Auxiliary regulated 24V/ 0.15A output for Subsystems, permanently available
    • line input, built-in EMI-filter: meets CE and FCC

Additional information

For Manufacturer

, ,

Type (Ushio)

,

Type (Osram)

Type (Superior Quartz)

,

ELECTRICAL DATA

All values are valid at 25 ± 5°C, unless otherwise noted.

INPUT DATA
Nominal OperationSymbolUnitNominalTolerancesRemarks
Input voltage AC-LineUV AC180-240160-264-
Input voltage DC-LineUV DC180-320 DC-input is possible but not certified
System wattagePLineW-1000-2000Depends on P select
Input currentILIA-12Depends on P select
Line frequencyf inHz50/6047-63-
Line power factorPFC11.00.93 to 1.0-
Line inrush current limitingApeak-30Limiting Element will be shorted by Relais
Leakage Current to PEILeak_SAµA<1000@230 V-Standalone
OTHER OPERATION DATA
SymbolUnitNominalTolerancesRemarks
System wattage during ignitionPLineW25<30-
System wattage standby-operationPLIStbyW1.50.5-2.0-
LAMP OUTPUT DATA
IGNITIONSymbolUnitNominalTolerancesRemarks
Ignition voltage withZG120XeUignkVpeak30-35-Depends on ignitor
Ignition timetign outsec.10.9-1.1-
automatic restart countersec.5-Attempts (Ballast)
Run-up Operation
SymbolUnitNominalTolerancesRemarks
Run-up Current = nominalImaxA110Inside specified lamp- parameter (select by preset switch)
NOMINAL OPERATION
SymbolUnitNominalTolerancesRemarks
Lamp voltageULaV10-36PSU output NOT Ignitor input
Lamp wattagePLaW900 to 1800Factory set-up 2000W
Lamp currentILaAup to 110Depend on set-up
End-Of Life-Cut off voltageULa, maxV40+/- 1VAfter run-up completed
End-Of-Life-Cut off timetEOL-OffS<0.2
RF-Ripple of output power∆PLarip/
PLa
%<1 p-p
50Hz-60Hz Ripple%<1 p-p<4 p-p
Shift in output power with shift∆PLa/1<0.005with nominal values
in input voltage∆ULI
Open circuit voltage for ignitionUV110105-120