ROTEC Lighting Product

Electronic Xenon PSU
300W
HBX 300

Power Supply for Xenon Lamps

Datasheet

Description

Power Supply for Xenon Lamps

Features

  • Power supply for metal halide short arc, low voltage DC-lamps
  • Xenon and mercury, in the power range of 100 W to 300 W
  • Output power customer selectable by 16 step-switch
  • Certified by UL 60601, OSRAM and USHIO
  • Input voltage range from 90 V AC to 264 V AC, power factor corrected line input, built-in EMI-filter: meets CE and FCC part “A”
  • Special newly designed anti aging and anti abnormal arc control circuit for high optical reliability over extended life time
  • μP controlled, digital power management with high output stability over lamp lifetime
  • Output short circuit protected and “Arc to Ground” protected
  • Output galvanicly separated to line input, thermal shut off at 90°C
  • Shut off function for end of life and lamp fail parameter
  • Less than 1% rms light flicker at all frequencies
  • Auxiliary regulated 24 V / 0.2 A output for fan drive, (only available when lamp lit.)
  • Flexible design: new lamps and functions adaptable only by software

Additional information

For Manufacturer

, ,

Type (Ushio)

, , , , ,

Type (Osram)

,

Type (Superior Quartz)

, , ,

ELECTRICAL DATA

All values are valid at 25 ± 5°C, unless otherwise noted

INPUT DATA
Nominal OperationSymbolUnitNominalTolerancesRemarks
Input voltage AC-LineUV AC100 - 24090 - 264
System wattagePLIW150 - 350Depends on select
Input currentILIA0.6 - 1.4Depends on select
Line frequencyFinHz50/6047 - 63
Line power factorPFC11.00.93 - 1.0
OUTPUT DATA
IgnitionSymbolUnitNominalTolerancesRemarks
Ignition voltageUignkVpeak± 14± 12 - ± 16Load capacity < 20 pF
Ignition timetign onsec.10.9 - 1.1
Nominal Operation
Lamp voltageULaV10 - 29± 5%Depends on lamp select
Lamp wattagePLaW150, 180, 200,
250, 300
± 2%Selectable by mode sw.
Lamp currentILaADepend on select
End-Of Life-Cut off voltageU La, maxV30± 2 V
End-Of-Life-Cut off timet EOL-Offs< 0.2
LIFETIME DATA · All values for Uu = 230 V mrs, Temperature at test point = 70°C
SymbolUnitNominalTolerancesRemarks
Ballast lifetimetLifeh25.000>25.000Acc. to MIL HDBK for
nominal operation
MISCELLANEOUS DATA
SymbolUnitNominalTolerancesRemarks
Power losses at 115 V
Power losses at 115 V
PVW20 - 65
15 - 55
±Depends on power select
Efficiencyη10.830.8 - 0.9Depend on lamp current
Ambient temperatureTA°C+ 25-10 - +50Non condensing
Maximum temperature at test pointT C°C+ 80Case surface near output at U-profile
Internal temp. switch off temperatureT C-off°C+ 90+ 85 - + 95At heatsink no derating till switch off
GEOMETRY AND WEIGHT
SymbolUnitNominalTolerancesRemarks
Length x width x heightL x W x Hmm180 x 102 x 43± 1
HousingOpen case Al-profile
WeightWBkg0.7± 0.05