ROTEC Lighting Product

Electronic Control System
200W
ELDC 2

Electronic Control System for DC Lamps 100 – 200 W

Datasheet

Description

Electronic Control System for DC Lamps 100 – 200 W

Features

  • Power Supply for Metal Halide DC-lamps, Xenon and Mercury, in the power range of 100 W to 200 W
  • Operating Voltages between 36 and 98 V, other ranges possible with modifications
  • Output power selection by solder bridges in 6 steps / 20 W
  • Certified by USHIO
  • Input voltage range from 90 V AC to 264 V AC, power factor corrected line input, built-in EMI-filter: meets CE and FCC part “A”
  • Special newly designed anti aging and anti abnormal arc control circuit for high optical reliability over extended lifetime.
  • uP controlled, Digital Power Management with high output stability over lamp lifetime.
  • Output short circuit protected
  • Thermal shut off at 90°C
  • Shut off function for end of life and lamp fail parameter
  • Photo feedback terminal
  • less than 1% rms light flicker at all frequencies under full load
  • auxiliary 24 V / 200 mA output at 2 terminals for fan drive, only available when the lamp is in operation.
  • UL60950-1 certified, UL 60601 compliant

Additional information

For Manufacturer

,

Type (Ushio)

Type (Osram)

,

ELECTRICAL DATA

All values are valid at 25 ± 5°C, unless otherwise noted

INPUT DATA
Nominal OperationSymbolUnitNominalTolerancesRemarks
Input voltage AC-LineUV AC100 - 24090 - 264
Input voltage DC-LineUV DCDC input not allowed, fuse is only rated for AC
System wattagePLIW200100 - 200Depends on preset
Input currentILIA1 - 3
Line frequencyFinHz50/6047 - 63
Line power factorPFC11.0> 0.93
Other Operation Data
System wattage during ignitionPlignW25< 30
System wattage standbyoperationPLIStbyW10.5 - 2.0
OUTPUT DATA
IgnitionSymbolUnitNominalTolerancesRemarks
Ignition voltageUignkVpeak± 14 V± 12 - ± 16Load capacity < 20 pF
Ignition timetign onsec.10.9 - 1.1
Run-up Operation
Run-up currentlmax
lmax
A
A
5.7
5.7
5.6 - 5.8
5.6 - 5.8
< = 20 V ULa
20 V < ULa     < 36 V
In rush currentlmaxA6± 10%For 1..10 s
Nominal Operation
Lamp voltageULaV6036 - 95
Lamp wattagePLaW100 - 200Presetable in 6 steps continous
variable from preset to 200 W by
optocoupler
Lamp currentILaAImax
= 5.7 A
End-Of Life-Cut off voltageU La, maxV9899 - 101
End-Of-Life-Cut off timet EOL-Offs< 0.2
HF-Ripple of output powerPLa,rip
P La
%< 1 rms40 V ULa     80 V
50 Hz - 60 Hz ripple%< 2 p-pTyp. < 1%
Shift in output power with
shift in input voltage
∆ P La
∆ U Ll
1< 0.005Within nominal values
Open circuit voltageU OCVV240230 - 260
LIFETIME DATA · All values for Uu = 230 V mrs, Temperature at test point = 70°C
SymbolUnitNominalTolerancesRemarks
Ballast lifetimetLifeH25.000>25.000Acc. to MIL HDBK for
nominal operation
GEOMETRY AND WEIGHT
SymbolUnitNominalTolerancesRemarks
Length x width x heightL x W x Hmm180 x 71 x 40
Housing
WeightWBkg0.427