Electronic Modular Power Supply for Xe Lamps
Parallel Operation of 2 x HBX3000-50

Description

Electronic Modular Power Supply for Xe Lamps

Parallel Operation of 2 x HBX3000-50

Suiting Ignitor:

  • ZG 180Xe with asymmetric ignition (Ri=650 μΩ)
  • Anode or Cathode Ground operating
  • Designed for Xenon short arc lamps rated up to 7000W/ 42V, 160A
  • Output power selectable by control Voltage 0-5V and/or presetting by Hex switch and adjustment Pot
  • Capable to drive lamp voltage range up to 50V (switch off @ 52V)
  • Designed according to IEC 61010 and IEC 60601 / HALT tested
  • Input voltage 240V AC, 220-262V, PF corrected
  • μP controlled, digital power management with high output stability over lamp Lifetime
  • Output short circuit protected and “Arc to Ground” protected
  • Operation with Cathode or Anode to Ground/PE possible
  • Galvanic separation of lamp output to line input, thermal shut off at 90°C
  • Shut off function for end of life and lamp fail parameter
  • PSUs cascadable for use for higher wattage Xenon lamps
  • Auxiliary regulated 24V/ 0.15A output for Subsystems, permanent available
  • line input, built-in EMI-filter: meets CE and FCC

Additional information

For Manufacturer

,

Type (Ushio)

,

Type (Osram)

ELECTRICAL DATA

All values are valid at 25 ± 5°C, unless otherwise noted.

INPUT DATA
Nominal OperationSymbolUnitNominalTolerancesRemarks
Input voltage AC-LineUV AC230V/typ.90-264-
System wattagePLIW-Up to 7400Depends on P select
Input currentILIA30< 90Depends on P select
Line frequencyf inHz50/6047-63-
Line power factorPFC11.00.93 to 1.0-
Line inrush current limitingILI, PeakA100Limiting Element will be shorted by Relais
Leakage Current to PEILeak_SAµA<1000@230 V-Standalone
OTHER OPERATION DATA
SymbolUnitNominalTolerancesRemarks
System wattage during ignitionPLignW200<4000-
System wattage standby-operationPLIStbyW10<12-
LAMP OUTPUT DATA
IGNITIONSymbolUnitNominalTolerancesRemarks
Ignition voltage withZG180XeUignkVpeak36-46-Depends on ignitor
Ignition timetign outsec.10.9-1.1-
automatic restart counter20-Attempts (Ballast)
Run-up Operation
SymbolUnitNominalTolerancesRemarks
Run-up Current = nominalImaxA200Inside specified lamp- parameter (select by preset switch)
NOMINAL OPERATION
SymbolUnitNominalTolerancesRemarks
Lamp voltageULaV25-50After run-up complete
Lamp wattagePLaWup to 7000Factory set-up 6700W
Lamp currentILaAup to 160Depend on set-up
End-Of Life-Cut off voltageULa, maxV52+/- 1VAfter run-up completed
End-Of-Life-Cut off timetEOL-OffS<0.2
RF-Ripple of output power∆PLarip/PLa%<1
50Hz-60Hz Ripple%<1<4 p-p
Shift in output power with shift in input voltage∆PLa,rip /∆U LI 1<0.005with nominal values
Open circuit voltage for ignitionUOCVV110105-160