Datasheet

HR self stopping ignitor for MH and Hg lamps

Features

  • For AC, DC-Hg and Xenon discharge lamps
  • Suitable for lamps with operating voltages up to 250 V AC or DC
  • Nominal Current of up to 60 A
  • Threshold Voltage of about 185 V
  • Symmetrical ignition Voltage 60 KVpp
  • Compliant to RoHS-directive 2011/65/EC
  • Self dynamical timing operation
  • Extremely low noise operation @ rectangle waveforms
  • Suitable for lamps with operating voltages up to 250 V AC
  • Nominal current of up to 60 A with natural convection
  • Self dynamical timing operation
  • Extremely low noise operation @ rectangular waveforms
  • Single Phase operation of 230 Vrms – 40 Hz – 440/Hz
  • DC and rectangular input voltage of up to 400 Vrms
  • Terminals for M6 screws and cable shoes