ROTEC Lighting Product

2 x HBX 2000

Modular Electronic Control Gear for DC short arc lamps up to 2000W

Datasheet

Description

Modular Electronic Control Gear for DC short arc lamps up to 2000W

Features

    • Designed for Xenon short arc lamps rated up to 2200W/ 102A
    • Output power selectable by control Voltage 0-5V and/or presetting by Hex switch and adjustment Pot
    • Capable to drive lamp voltage range up to 40V (switch off @ 41V)
    • Ballast boards inside has IEC(UL) 60601 approval
    • Input voltage range from 110V AC to 240V AC, (90V-262V) PF corrected
    • μP controlled, digital power management with high output stability over lamp Lifetime
    • Output short circuit protected and “Arc to Ground” protected
    • Operation with Cathode or Anode to Ground/PE possible
    • Galvanic separation of lamp output to line input, thermal shut off at 90°C
    • Shut off function for end of life and lamp fail parameter
    • PSUs cascadable for use for higher wattage Xenon lamps
    • Auxiliary regulated 24V/ 0.15A output for Subsystems, permanently available
    • line input, built-in EMI-filter: meets CE and FCC

Additional information

For Manufacturer

, ,

Type (Ushio)

Type (Osram)

,

ELECTRICAL DATA

All values are valid at 25 ± 5°C, unless otherwise noted.

INPUT DATA
Nominal OperationSymbolUnitNominalTolerancesRemarks
Input voltage AC-LineUV AC110-24090-264-
Input voltage DC-LineUV DC 150-320 DC-input is possible but not certified
System wattagePLineW-1000-2400Depends on P select
Input currentILIA-32Depends on P select
Line frequencyf inHz50/6047-63-
Line power factorPFC11.00.93 to 1.0-
Line inrush current limitingApeak-50Limiting Element will be shorted by Relais
Leakage Current to PEILeak_SAµA<1000@230 V-Standalone
OTHER OPERATION DATA
SymbolUnitNominalTolerancesRemarks
System wattage during ignitionPLineW100<150-
System wattage standby-operationPLIStbyW5<6-
LAMP OUTPUT DATA
IGNITIONSymbolUnitNominalTolerancesRemarks
Ignition voltage withZG120XeUignkVpeak36-46-Depends on ignitor
Ignition timetign outsec.10.9-1.1-
automatic restart countersec.20-Attempts (Ballast)
Run-up Operation
SymbolUnitNominalTolerancesRemarks
Run-up Current = nominalImaxA102Inside specified lamp- parameter (select by preset switch)
NOMINAL OPERATION
SymbolUnitNominalTolerancesRemarks
Lamp voltageULaV22-40PSU output NOT Ignitor input
Lamp wattagePLaW1100 to 2400Factory set-up 2000W
Lamp currentILaAup to 102Depend on set-up
End-Of Life-Cut off voltageULa, maxV41+/- 1VAfter run-up completed
End-Of-Life-Cut off timetEOL-OffS<0.2
RF-Ripple of output power∆PLarip/
PLa
%<1
50Hz-60Hz Ripple%<1 p-p<4 p-p
Shift in output power with shift ∆PLa/1<0.005with nominal values
in input voltage∆ULI
Open circuit voltage for ignitionUV110105-160